ZT GAS MIXER GAS WGM50-2 FLX

  • Detail
  • Parameters

The ZT GAS mixing ratio system is suitable for a variety of Industrial gas technology applications.Designed for low maintenance and ease of operation.

Advance mixing ratio technology, without the need for a buffer tank or power supply.


Advantage

l The mixing accuracy is not affected by changes in gas consumption (within the applicable range)

l Automatic stop mixing function: If one of the gas sources interrupts the gas supply, the mixer will automatically stop working

l Adopting a stainless steel casing, it can be installed outdoors and adjustment is inside the casing to prevent unauthorized adjustment.

Benefits

l High mixing accuracy

l avoids the need to stock multiple pre-mixes

l does not require receiver

l inlet gas filters protect the device against impurities

l pneumatic operating principle, no electrical required

l mixed gas production from 3 l/min to the max. flow

l robust, compact design

l Panel mount for wall mounting

l minimal maintenance required


Option

Optional Remote monitoring function:

- built-in inlet pressure alarm module,

- digital pressure display (when using analog pressure transmitter)

- alarm monitoring with parameter setting

- Historical data monitoring

- Remote monitoring through mobile Apps


Technical Parameter

Type

WGM50-2 FLX

Gases

N2,CO2,Ar or others as wellas their mixtures!

Mixing range

2-95%

Background gas

Ar/N2/CO2

Setting accuracy

±0.5% absolute

Dimensions(HxWxD)

approx.579x404x238mm   without connections

Housing

Stainless steel

Weight is pproximately

Approx. 15...57kg

Temperature

-10°C bis   50°C

Design pressure

25bar

Gas inlet connection method

G1/2 RH M

Gas outlet connection method

G1/2 RH M


Flow comparison table:

Note: The determined data of mixture output are only in relation to N2!

The use of other required gases results in a difference to the mixture output, which is compensated by the

correction factor FMIX.

Corresponding table of mixed gas and mixing ratio (example):

gas mixture

CO2

AR

mixing coefficient

Mixed vole%

10

90

0.854

Mixed vole%

20

80

0.888

gas mixture

He

AR

mixing coefficient

Mixed vole%

25

75

0.8775

Mixed vole%

90

10

1.027

gas mixture

O2

AR

mixing coefficient

Mixed vole%

10

90

0.826

Mixed vole%

25

75

0.835

gas mixture

H2

AR

mixing coefficient

Mixed vole%

5

95

0.834

Mixed vole%

10

90

0.849

gas mixture

O2

CO2

mixing coefficient

Mixed vole%

20

80

1.104

Mixed vole%

85

15

0.922

gas mixture

He

N2

mixing coefficient

Mixed vole%

10

90

1.045

Mixed vole%

50

50

1.025

gas mixture

O2

N2

mixing coefficient

Mixed vole%

4

96

0.9952

Mixed vole%

25

75

0.97

gas mixture

CO2

N2

mixing coefficient

Mixed vole%

5

95

1.008

Mixed vole%

30

70

1.048

gas mixture

H2

N2

mixing coefficient

Mixed vole%

5

95

1.006

Mixed vole%

20

80

1.022

If you have more needs, please consult ZTGAS!

   


Example:   VN2=10Nm3/H   (See Flow comparison table )                                                                    

Gas mixture setting:

Gas mixture(CO2 in Ar)[%]

5

95

Gas mixture conversion factor( Fmix)

0,837

Gas mixture flow rate [m3/h]

10 x 0.837=8,37

Gas mixture(CO2 in N2)[%]

5

95

Gas mixture conversion factor( Fmix)

1,008

Gas mixture flow rate [m3/h]

10 x 1,008=10,08

Gas mixture(He in Ar)[%]

25

75

Gas mixture conversion factor( Fmix)

0,8775

Gas mixture flow rate [m3/h]

10 x 0,8775=8,775

Gas mixture(O2 in Ar)[%]

4

96

Gas mixture conversion factor( Fmix)

0,8224

Gas mixture flow rate [m3/h]

10 x 0,8224=8,224

Gas mixture setting:

Gas mixture(He in N2)[%]

10

90

Gas mixture conversion factor( Fmix)

1,045

Gas mixture flow rate [m3/h]

10 x 1,045=10,45

Gas mixture(O2 in N2)[%]

4

96

Gas mixture conversion factor( Fmix)

0,9952

Gas mixture flow rate [m3/h]

10 x 0,9952=9,952

Gas mixture(O2 in CO2)[%]

20

80

Gas mixture conversion factor( Fmix)

1,104

Gas mixture flow rate [m3/h]

10 x 1,104=11,04

Gas mixture(H2 in N2)[%]

5

95

Gas mixture conversion factor( Fmix)

1,006

Gas mixture flow rate [m3/h]

10 x 1,006=10,06


Origin
Singapore
Type
Mixer
Specification
WGM50-2 FLX
Color
Stainless Steel Color
Brand
ZTGas
Model
WGM15/25/50/75/100-2
Home